Vertiv Liebert MPH2 Metered Outlet Switched Rack Mount PDU

$520.95

plus Shipping Costs

Liebert® MicroPOD allows manual uninterruptible power supply (UPS) bypass, powering the connected load with utility power during UPS maintenance or replacement, to ensure continuous operation of critical computer equipment. The unit has two modes of operation, UPS mode (UPS available) and utility mode (maintenance bypass). The rackmount unit can support any brand of UPS, 3kVA or smaller; in 50Hz or 60Hz models.

More from the Manufacturer


  • Operates with any brand of UPS, 3kVA or smaller
  • Installs with plug-and-play ease
  • Allows continuous operation for connected equipment during UPS maintenance or replacement
  • Manual switchover from UPS to utility power

APC by Schneider Electric Rack ATS, 208V, 30A, (2) L6-30P in, (1) L6-30R Out

$2,295.00

plus Shipping Costs

APC Rack Automatic Transfer Switches (rack ATS) provide reliable, redundant rack mount power to single-corded equipment. The rack ATS has dual input power cords supplying power to the connected load. If the primary power source becomes unavailable, the rack ATS will seamlessly source power from the secondary source without interrupting critical loads. The Rack ATS has built-in network connectivity, which allows for remote management via Web, SNMP, or Telnet interfaces.
  • 10 kAIC Overcurrent Protection - Provides protection in the event of a significant overcurrent event.
  • Command line interface - Offers simultaneous remote management access through Telnet and SSH
  • Current Monitoring - Monitors the aggregate current draw per power distribution unit.
  • Cyber security - A cyber-secure connection provides improved security for your infrastructure devices, and machine data forms the basis of operational insights and analytics, aimed at reducing equipment maintenance costs.
  • Local Current Monitoring Display - The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
  • Quick Transfer Rate - Transfer rate is within the industry standard and within the time power supplies will typically drop loads. The transfer of one power source to another is seamless to the connected equipment avoiding disruption of equipment performance.
  • Remote Management Capabilities - Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Command Line Interface. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
  • RoHS - Certifies that electronic devices don't contain hazardous metals and flame retardants
  • StruxureWare Data Center Expert compatible - Enables centralized management via StruxureWare Data Center Expert.

Vertiv Liebert MPH2 Metered Outlet Switched Rack Mount PDU

$616.95

plus Shipping Costs

Liebert® MicroPOD allows manual uninterruptible power supply (UPS) bypass, powering the connected load with utility power during UPS maintenance or replacement, to ensure continuous operation of critical computer equipment. The unit has two modes of operation, UPS mode (UPS available) and utility mode (maintenance bypass). The rackmount unit can support any brand of UPS, 3kVA or smaller; in 50Hz or 60Hz models.

More from the Manufacturer


  • Installs with plug-and-play ease
  • Operates with any brand of UPS, 3kVA or smaller
  • Manual switchover from UPS to utility power
  • Allows continuous operation for connected equipment during UPS maintenance or replacement

Liebert MicroPOD MP2-130HW 24A Maintenance Bypass Switch

$600.95

plus Shipping Costs

The MicroPOD MP2-130HW 24A Maintenance Bypass Switch allows a transfer of the critical AC load from the UPS inverter to the utility source; to allow for service to or replacement of the UPS, without interrupting the load.

Vertiv Liebert MPH2 Metered Rack Mount PDU

$612.00

plus Shipping Costs

Liebert® MicroPOD allows manual uninterruptible power supply (UPS) bypass, powering the connected load with utility power during UPS maintenance or replacement, to ensure continuous operation of critical computer equipment. The unit has two modes of operation, UPS mode (UPS available) and utility mode (maintenance bypass). The rackmount unit can support any brand of UPS, 3kVA or smaller; in 50Hz or 60Hz models.

More from the Manufacturer


  • Operates with any brand of UPS, 3kVA or smaller
  • Installs with plug-and-play ease
  • Allows continuous operation for connected equipment during UPS maintenance or replacement
  • Manual switchover from UPS to utility power

Liebert MicroPOD Maintenance Bypass Panel

$532.95

plus Shipping Costs

The Liebert MicroPOD maintenance bypass and power output distribution switch allows you to manually transfer the connected equipment to utility power via a maintenance bypass switch, permitting scheduled maintenance or UPS replacement without discontinuing power to the critical load. Transferring back to UPS power is just as easy simply turn the switch to the indicated position and the load is protected by the UPS.

Tripp Lite UPS Maintenance Bypass Panel for SUTX20K – 4 Breakers

$4,692.60

plus Shipping Costs

UPS Maintenance Bypass Panel Keeps Equipment Powered During UPS Maintenance

This wall-mount four-breaker maintenance bypass panel is compatible with Tripp Lite's SUTX20K 3-phase UPS system. It allows you to reroute power around the UPS, providing an alternate path for electricity that keeps the connected load operational while the UPS is offline for maintenance or repairs.

Features 4 Built-In Circuit Breakers to Isolate Loads

Four 4-pole circuit breakers are connected to heavy-duty buswork and isolate the UPS system from its connected load with no loss of network availability. This allows the load to remain continuously powered without costly downtime. A Kirk-key interlock system enhances safety and security. Removable handles allow the panel's trim cover to be removed for internal access. The 80A unit has a kAIC rating of 10K.

Switching Between Normal and Bypass Modes Is Easy

When a UPS needs maintenance, this UPS bypass panel keeps power supplied to components via its mechanical interlock system by switching power to the external bypass breaker. Simply unscrew the interlock switch, rotate the switch from the UPS AC input breaker (SW1) to the bypass breaker (SW2), then turn on the bypass breaker and turn off the UPS and isolation breaker (SW3) to perform UPS maintenance without service interruption.

Convenient Wall-Mount Installation

Made of galvanized steel, the service bypass panel has rear mounting holes for installation on a smooth, solid wall (mounting hardware not included).


  • Isolates UPS from connected loads for maintenance without losing network availability
  • Maintenance bypass panel mounts to wall next to UPS for convenient access
  • 80A 10 kAIC unit has four 4-pole circuit breakers connected to heavy-duty buswork
  • Secure Kirk-key interlock system prevents unauthorized access to power
  • Compatible with Tripp Lite's SUTX20K 3-phase UPS system
  • 1-year limited warranty

Vertiv Liebert MicroPOD – (8) NEMA 5-20R| 24A| UPS Maintenance Bypass/Switch

$610.95

plus Shipping Costs

The Vertiv Liebert MicroPod External Maintenance Bypass POD (MP2-130C) is an external power output distribution (POD) unit and maintenance bypass switch for your uninterruptible power supply (UPS) unit. With the MicroPod, you can avoid initiating unnecessary downtimes during UPS maintenance or replacements. It allows the manual transfer of power from the UPS to the utility source without power interruption to the connected load, ensuring continuous uptime for your critical operations. The MicroPod MP2-130C is designed for the Vertiv Liebert GXT and Vertiv Liebert PSI UPS 3kVA models and below, but is compatible with other UPS brands as well. It comes with brackets for easy rack mounting and is equipped with three NEMA L5-30P input connectors. The MicroPOD has eight NEMA 5-20R output connectors and is available at 120V and supports a max current of 24A.

More from the Manufacturer


  • Comes with two-year, full-unit, and no-hassle replacement warranty
  • Output: Eight (8) NEMA 5-20R
  • Input: Three (3) NEMA L5-30P
  • Max Current: 24Amps
  • AC 120V
  • Shipped with mounting brackets for easy mounting on any standard 19" rack, oin the floor, or on the wall
  • Designed for Vertiv Liebert PSI and Vertiv Liebert GXT UPS but is compatible with any UPS brand 3kVA models or lower
  • Avoid initiating unnecessary downtimes during UPS maintenance or replacement

Eaton Bypass Module

$1,227.00

plus Shipping Costs

Eaton Bypass Module - Hardwired, 3 x NEMA L6-30R - 11000 VA - 208 V AC

Tripp Lite UPS Maintenance Bypass Panel SV100KL, SV120KL 3Ph UPS 3 Breakers

$9,549.00

plus Shipping Costs

UPS Maintenance Bypass Panel Keeps Equipment Powered During UPS Maintenance

This wall-mount three-breaker maintenance bypass panel is compatible with Tripp Lite's SV100KL and SV120KL 3-phase UPS systems. It allows you to reroute power around the UPS, providing an alternate path for electricity that keeps the connected load operational while the UPS is offline for maintenance or repairs.

Features 3 Built-In Circuit Breakers to Isolate Loads

Three circuit breakers - an AC input breaker, a maintenance bypass breaker and a maintenance isolation breaker - are connected to heavy-duty buswork and isolate the UPS system from its connected load with no loss of network availability. This allows the load to remain continuously powered without costly downtime. A Kirk-key interlock system enhances safety and security. Removable handles allow the panel's trim cover to be removed for internal access. The 400A unit has a kAIC rating of 10K.

Switching Between Normal and Bypass Modes Is Easy

When a UPS needs maintenance, this UPS bypass panel keeps power supplied to components via its mechanical interlock system by switching power to the external bypass breaker. Simply unscrew the interlock switch, rotate the switch from the UPS AC input breaker (SW1) to the bypass breaker (SW2), then turn on the bypass breaker and turn off the UPS and isolation breaker (SW3) to perform UPS maintenance without service interruption.

Convenient Wall-Mount Installation

Made of galvanized steel, the service bypass panel has rear mounting holes for installation on a smooth, solid wall (mounting hardware not included).


  • Compatible with Tripp Lite SV100KL and SV120KL 3-phase UPS systems
  • 1-year limited warranty
  • Secure Kirk-key interlock system prevents unauthorized access to power
  • 400A 10 kAIC unit has 3 built-in circuit breakers connected to heavy-duty buswork
  • Maintenance bypass panel mounts to wall next to UPS for convenient access
  • Isolates UPS from connected loads for maintenance without losing network availability

Tripp Lite Wall Mount Kirk Key Bypass Panel 240V for 80kVA 3-Phase UPS

$23,760.00

plus Shipping Costs

The SU80KMBPK Maintenance Bypass Panel is a wallmount 3 breaker manual bypass panel with Kirk Key interlock system isolates the UPS from connected loads for maintenance with no loss of network availability.


  • Compatible with select Tripp Lite 3 phase UPS systems
  • 3 built-in circuit breakers, heavy duty buswork
  • Includes Kirk-Key interlock system enhances system reliability
  • Wallmount manual bypass panel isolates UPS from connected loads for maintenance with no loss of network availability

Eaton Tripp Lite Series SmartOnline Maintenance Bypass for Select 5kVA to 6kVA SmartOnline UPS Systems, 2 L6-30R and 2 L6-20R Outlets, 0U

$750.00

plus Shipping Costs

Compatible with Select 5kVA/6kVA SmartOnline UPS Systems

The SUPDMBP6K works with the SmartOnline® SU5000RT, SU5000RTF, SU6000RT and SU6000RTF UPS systems (it comes included with the SU5000RTMB, SU6000RTMB, SU5000RTFMB and SU6000RTFMB). The bypass switch transfers the load to utility power in case of an overload or internal fault in the UPS. This allows you to service or replace the UPS without powering down any connected equipment or risking costly downtime. Two NEMA L6-20R and two NEMA L6-30R dongle outlets allow load connection. The SUPDMBP6K supports 0U mounting to save space and increase airflow in a crowded rack enclosure. AC input connection options include a terminal block for hardwire input/output or use of a NEMA L6-30P cord (10-foot cord included with compatible UPS models).


  • Isolates UPS from connected loads for maintenance without powering down equipment
  • Designed for 0U mounting to save space and increase airflow in a crowded rack
  • Compatible with SmartOnline SU5000RT and SU6000RT Series UPS systems
  • 2-year limited warranty

Tripp Lite UPS Maintenance Bypass Panel for SUT20K – 3 Breakers

$4,885.20

plus Shipping Costs

Bypass an SUT20K UPS to Perform Maintenance

For use with Tripp Lite's SUT20K 3-phase UPS system, the SUT20KMBP maintenance bypass panel (MBP) maintains total continuity of power to connected load circuits when bypass of the UPS is required for regular service and maintenance. This UPS maintenance bypass panel has three 4-pole circuit breakers for Input, Bypass and Output. The breakers have removable handles to allow the panel's trim cover to be removed for internal access. The short circuit rating is 10 kAIC. Maximum current capacity is 80A.

Convenient Wall-Mount Installation

Made of galvanized steel, the service bypass panel has rear mounting holes for installation on a smooth and solid wall (mounting hardware not included).

One-Year Warranty

The SUT20KMBP is backed by a one-year limited warranty, ensuring reliability and performance.


  • Isolates a Tripp Lite SUT20K UPS from connected loads to permit maintenance
  • Allows connected loads to remain continuously powered
  • Three built-in 4-pole circuit breakers for Input, Bypass and Output
  • Mounting holes for convenient wall installation
  • Maximum current capacity is 80A

Liebert MicroPOD MBS MP2-115HW 2U Tower/Rack Mountable 12A 15 A

$503.95

plus Shipping Costs

The MicroPOD allows you to manually transfer your connected equipment to utility power via a maintenance bypass switch, permitting scheduled maintenance or UPS replacement without power disruption. Transferring back to UPS power is just as easy just turn the switch to the indicated position and your load is protected by the UPS.

Vertiv Liebert Maintenance Bypass Cabinet 20KVA| 208V/120V – (3) L14-30R

$3,600.00

plus Shipping Costs

The Vertiv Liebert MBC 20KVA (VMBC-20KMVRT4U) is a maintenance bypass cabinet with power output distribution. Designed for Vertiv Liebert GXT5 15-20kVA and the APS 1/2/5/6 uninterruptible power supply (UPS) models, it is an accessory that allows you to perform UPS maintenance and/or replacement without power interruption to the connected load. It has three (3) L14-30R outlets, space for an optional PD2 POD, and has an input/output terminal block for hardwiring of the AC input source and output (if needed). It includes simplified intra/inter-rack connections and has a 5-year warranty.


  • Easy-to-use Maintenance Bypass Cabinet for larger single-phase UPS such as Vertiv Liebert GXT5 15-20kVA and the APS 1/2/5/6 UPS models
  • Ensures continuous uptime while performing UPS maintenance and/or replacement
  • Includes Integrated Intra/Inter-Rack Power Output Distribution
  • Output: (3) L14-30R + (Optional) PD2 + Hardwired
  • Input: Hardwired

APC by Schneider Electric NetShelter Automatic Transfer Switch

$1,367.44

plus Shipping Costs

APC by Schneider Electric NetShelter Automatic Transfer Switch - 10 x NEMA 5-20R - 20 A

Tripp Lite UPS Maintenance Bypass Panel for SUT60K – 3 Breakers

$8,859.60

plus Shipping Costs

Bypass an SUT60K UPS to Perform Maintenance

For use with Tripp Lite's SUT60K 3-phase UPS system, the SUT60KMBP maintenance bypass panel (MBP) maintains total continuity of power to connected load circuits when bypass of the UPS is required for regular service and maintenance. This UPS maintenance bypass panel has three 4-pole circuit breakers for Input, Bypass and Output. The breakers have removable handles to allow the panel's trim cover to be removed for internal access. Maximum current capacity is 225A.

Convenient Wall-Mount Installation

Made of galvanized steel, the service bypass panel has rear mounting holes for installation on a smooth and solid wall (mounting hardware not included).

One-Year Warranty

The SUT60KMBP is backed by a one-year limited warranty, ensuring reliability and performance.


  • Isolates a Tripp Lite SUT60K UPS from connected loads to permit maintenance
  • Allows connected loads to remain continuously powered
  • Three built-in 4-pole circuit breakers for Input, Bypass and Output
  • Mounting holes for convenient wall installation
  • Maximum current capacity is 225A

Tripp Lite UPS Maintenance Bypass Panel for SUT40K – 3 Breakers

$8,433.00

plus Shipping Costs

Bypass an SUT40K UPS to Perform Maintenance

For use with Tripp Lite's SUT40K 3-phase UPS system, the SUT40KMBP maintenance bypass panel (MBP) maintains total continuity of power to connected load circuits when bypass of the UPS is required for regular service and maintenance. This UPS maintenance bypass panel has three 4-pole circuit breakers for Input, Bypass and Output. The breakers have removable handles to allow the panel's trim cover to be removed for internal access. Maximum current capacity is 150A.

Convenient Wall-Mount Installation

Made of galvanized steel, the service bypass panel has rear mounting holes for installation on a smooth and solid wall (mounting hardware not included).

One-Year Warranty

The SUT40KMBP is backed by a one-year limited warranty, ensuring reliability and performance.


  • Isolates a Tripp Lite SUT40K UPS from connected loads to permit maintenance
  • Allows connected loads to remain continuously powered
  • Three built-in 4-pole circuit breakers for Input, Bypass and Output
  • Mounting holes for convenient wall installation
  • Maximum current capacity is 150A

Tripp Lite UPS Maintenance Bypass Panel for SUT30K – 3 Breakers

$3,992.40

plus Shipping Costs

Bypass an SUT30K UPS to Perform Maintenance
For use with Tripp Lite's SUT30K 3-phase UPS system, the SUT30KMBP maintenance bypass panel (MBP) maintains total continuity of power to connected load circuits when bypass of the UPS is required for regular service and maintenance. This UPS maintenance bypass panel has three 4-pole circuit breakers for Input, Bypass and Output. The breakers have removable handles to allow the panel's trim cover to be removed for internal access. The short circuit rating is 10 kAIC. Maximum current capacity is 125A.

Convenient Wall-Mount Installation
Made of galvanized steel, the service bypass panel has rear mounting holes for installation on a smooth and solid wall (mounting hardware not included).

One-Year Warranty
The SUT30KMBP is backed by a one-year limited warranty, ensuring reliability and performance.


  • Isolates a Tripp Lite SUT30K UPS from connected loads to permit maintenance
  • Allows connected loads to remain continuously powered
  • Three built-in 4-pole circuit breakers for Input, Bypass and Output
  • Mounting holes for convenient wall installation
  • Maximum current capacity is 125A

Vertiv Liebert MicroPOD – (8) NEMA 5-15R| 12A UPS Maintenance Bypass/Switch

$448.95

plus Shipping Costs

The Vertiv Liebert MicroPod External Maintenance Bypass POD (MP2-115A) is an external power output distribution (POD) unit and maintenance bypass switch for your uninterruptible power supply (UPS) unit. With the MicroPod, you can avoid initiating unnecessary downtimes during UPS maintenance or replacements. It allows the manual transfer of power from the UPS to the utility source without power interruption to the connected load, ensuring continuous uptime for your critical operations. The MicroPod MP2-115A is designed for the Vertiv Liebert GXT and Vertiv Liebert PSI UPS 3kVA models and below, but is compatible with other UPS brands as well. It comes with brackets for easy rack mounting and is equipped with two NEMA 5-15P input connectors. The MicroPOD has eight NEMA 5-15 output connectors and is available at 120V and supports a max current of 12A.

More from the Manufacturer


  • Comes with two-year, full-unit, and no-hassle replacement warranty
  • Output: Eight (8) NEMA 5-15R
  • Input: Two (2) NEMA 5-15P
  • Max Current: 12Amps
  • AC 120V
  • Shipped with mounting brackets for easy mounting on any standard 19" rack, oin the floor, or on the wall
  • Designed for Vertiv Liebert PSI and Vertiv Liebert GXT UPS but is compatible with any UPS brand 3kVA models or lower
  • Avoid initiating unnecessary downtimes during UPS maintenance or replacement

Liebert Micro Pod 3kVA PDU

$520.95

plus Shipping Costs

The Vertiv Liebert MicroPod External Maintenance Bypass POD (MP2-120C) is an external power output distribution (POD) unit and maintenance bypass switch for your uninterruptible power supply (UPS) unit. With the MicroPod, you can avoid initiating unnecessary downtimes during UPS maintenance or replacements. It allows the manual transfer of power from the UPS to the utility source without power interruption to the connected load, ensuring continuous uptime for your critical operations. The MicroPod MP2-120C is designed for the Vertiv Liebert GXT and Vertiv Liebert PSI UPS 3kVA models and below, but is compatible with other UPS brands as well. It comes with brackets for easy rack mounting and is equipped with three NEMA 5-20P input connectors. The MicroPOD has eight NEMA 5-20R output connectors and is available at 120V and supports a max current of 16A.

More from the Manufacturer


  • Comes with two-year, full-unit, and no-hassle replacement warranty
  • Output: Eight (8) NEMA 5-20R
  • Input: Three (3) NEMA 5-20P
  • Max Current: 16Amps
  • AC 120V
  • Shipped with mounting brackets for easy mounting on any standard 19" rack, oin the floor, or on the wall
  • Designed for Vertiv Liebert PSI and Vertiv Liebert GXT UPS but is compatible with any UPS brand 3kVA models or lower
  • Avoid initiating unnecessary downtimes during UPS maintenance or replacement